03 Return Air Sensor Short Circuit (Check Alarm)

Thermo King Alarm Code
Description Corrective Action
Return Air Sensor Short Circuit (Check Alarm)
  • Sensor circuit resistance lower than 200 ohms.
  • Temperature above 80C (176F).
  • Indicates:
  • Short circuit to sensor
  • Defective or wrong sensor
  • Defective relay board
  • Defective cable No.1
  • Defective controller
  • Check sensor resistance between pins 3and 4 on plug J15. Resistance must be 2,000 ohms at 25C (77F).
  • Check cable No.1 between controller and relay board.