Mitsubishi Alarm Code #452 cause 4



Alarm Code #452
Model CPE52, 53, 14, 15, 15V, 16
Failure Disconnection or Internal thermostat actuation of Evaporator fan motor ( Hi : High speed )
Countermeasure
<< Cause –(4) >>
Current sensor CT1 shift
failure
< Check >
Refer to Page 125.
< Action >
Refer to Page 125.