Alarm Code #208
Model CPE52, 53, 14, 15, 15V, 16
Failure Power source frequency failure
Countermeasure
<< Cause >>
(1)Frequency is out of 45 – 66 Hz range.
(2)Power supply open phase failure.
< Check >
(1)Check the frequency display on the personal computer.
(2)Refer to Page 50 – 58.
< Action >
Improve the power supply frequency and wave form distortion.
Model CPE52, 53, 14, 15, 15V, 16
Failure Power source frequency failure
Countermeasure
<< Cause >>
(1)Frequency is out of 45 – 66 Hz range.
(2)Power supply open phase failure.
< Check >
(1)Check the frequency display on the personal computer.
(2)Refer to Page 50 – 58.
< Action >
Improve the power supply frequency and wave form distortion.