Mitsubishi Alarm Code #350 cause 3



Alarm Code #350
Model CPE52, 53, 14, 15, 15V, 16
Failure Current sensor ( CT1 ) High failure
Countermeasure
<< Cause –(3) >>
Offset data set error of CT1 sensor
< Check > ( Refer to Page F-22 )
Check if the CT1 current value displayed on personal computer is approx. ±0.5A range out of the measured CT1current value. ( Refer to Instruction Manual of Hand – held computer )
< Action >
Out of approx. ±0.5A range : Readjust.