| 302 | RH invalid |
|---|---|
| Description | Relative Humidity Sensor Invalid |
| Cause | Indication of defective relative humidity sensor or its measuring circuitry |
| Trouble shooting |
Possible causes:
Trouble shooting: Disconnect the cable for RH on the main controller according to the wiring schematics inside the control cabinet and from the RH sensor.
|
| Criteria | Value below alarm limit 10% RH or above 110% RH. Value invalid for 120 sec. for alarm activation. |