33 Condenser Temperature Sensor Short Circuit (Check Alarm)

Thermo King Alarm Code
Description Corrective Action
Condenser Temperature Sensor Short Circuit (Check Alarm)
  • Sensor circuit resistance lower than 200 ohms.
  • Temperature above 80 C (176 F)
  • Indicates:
  • Short circuit to sensor
  • Defective or wrong sensor
  • Defective relay board
  • Defective cable No. 1
  • Defective controller
  • Check sensor resistance between pins 7 and 8 on plug J15. Resistance must be 2,000 ohms at 25 C (77 F).
  • Check cable No. 1 between controller and relay board.

No comments :