Description
Probe Error
- Occurs during pretrip (PTI) test or probe test in
Chilled mode.
- Temperature difference between supply and return
air is above 1,5C and the system is not capable of
pinpointing which probe is failing.
- Temperature difference between supply and return
air and evaporator coil is above 1,5C and the
system is not capable of pinpointing which probe is
failing.
- Indicates:
- Sensor error.
- Sensor misplacement.
Corrective Action
- Using MANUAL FUNCTION TEST, ventilate
with evaporator fan high speed and evaluate
the readings.
- Check sensor connections.
- Replace sensor.
- Check sensor.