56 Compressor Temperature Too High (Shutdown Alarm) Model CSR

Thermo King Alarm Code
Description Corrective Action
Compressor Temperature Too High (Shutdown Alarm)
  • Compressor discharge temperature is above 148 C (298 F). Compressor stopped until discharge temperature decreases to normal;
  • Indicates:
  • Air in refrigeration system
  • Low refrigerant charge
  • Defective compressor or valve plate
  • Defective liquid injection system
  • Wrong or defective sensor
  • Check the refrigerant charge using the “Unit Health Check Procedure” on page 6-5. 
  • Enter Manual Function Test menu and test (operate) Injection Valve to determine if valve opens (energizes).
  • Check compressor discharge sensor resistance. Resistance must be 100,000 ohms at 25 C (77 F). 
  • Check discharge temperature with a separate electronic thermometer and compare to “HIGH PR TEMP” shown in the Data menu of controller.
NOTE: Unit will operate normally without compressor sensor. However, controller compressor high temperature protection is not active.

No comments :