Phase Sensor Error (Check Alarm)
- Occurs during Pretrip (PTI) or Function test only.
- During Phase Sensor Test, amperage difference between correct and wrong condenser fan rotation is more than 0.2 amps.
- Indicates:
- Defective phase relay
- Defective relay board
- Defective relay board cable No. 2
|
- Start a Function Test. During step F1.05, check whether the phase relays on relay board receive a signal (LED energizes). Verify that the relays respond and shift to reverse phase.
|