902 StarCool Alarm Codes And Actions

902 Battery malfunction
Description Battery Malfunctioning
Cause Indication of defective battery
Trouble
shooting
Possible causes:
  • The battery used for logging is defective.
Accompanied alarms:
  • AL 801 will be activated during FT- or PTI test.
Trouble shooting:
The battery is defective.
Dismount main controller, replace battery and remount main controller.
Criteria Battery voltage is below limit for low battery alarm 10V

No comments :