812 StarCool Alarm Codes And Actions

812 Mevap current OFF
Description Evaporator Motor Off Current Fault
Cause Indication of defective motor contactor or contactor driver circuitry
Trouble
shooting
Possible causes:
  • Defective evaporator motor contactor.
  • Defective contactor driver circuit.
Accompanied alarms.
  • N/A.
Trouble shooting:
  1. Check the evaporator motor contactor for defects. Replace the contactor.
  2. Check that the evaporator motor cables are mounted correctly
Criteria Evaporator fan motors have exceeded off current limit

No comments :