Mitsubishi Alarm Code #421 cause 1



Alarm Code #421
Model CPE52, 53, 14, 15, 15V, 16
Failure Lock or short circuit of Condenser fan motor
Countermeasure
<< Cause -(1) >>
Condenser fan motor start failure
< Check > ( Refer to Page F-10, 19 )
Operate the condenser fan motor under the test mode and check if the propeller fan revolves. And also check the current with the LED, the LCD or a clamp meter.
< Action >
In case the current is out of the following range, replace the condenser fan motor.
• CPE52, 53, : approx. 0.1 – 1.2A ( at AC 440V )
• CPE14, 15, 15V, 16 : approx. 0.3 – 3.0A ( at AC 440V )

No comments :