DAIKIN J CODE - P70 - J702 - Defrosting operation check

1. Defrosting operation check / Defrost time is too long. / Wrong installation of EOS. / Check the installation of EOS.

2. Defrosting operation check / Defrost time is too long. / EOS malfunction. / Check EOS.