Alarm Code #472
Model CPE52, 53, 14, 15, 15V, 16
Failure Disconnection of Evaporator coil heater
Hi ( All heaters )
Countermeasure
<<
Cause -(1) >> ( Refer to Page F-4, 5, 6,
7, 8 )
Poor
contact of the connector CN13 and the round connector of CT1,
and
looseness of the terminals related to the heater circuit.
<
Check >
Check
tightness of CN13 and the round connector of CT1, and check looseness of the
terminals.
<
Action >
Retighten the loose
parts and spray #2501S on the contact part of the connectors and the terminals.