Mitsubishi Alarm Code #998



Alarm Code #998
Model CPE52, 53, 14, 15, 15V, 16
Failure #998 : Mode change, #999 : Power supply OFF
Countermeasure
--- #998 ---
<< Cause >>
During PT1, Pre-Trip Inspection ( PT1 ) is cancelled with the mode key.