111 KVQ Heat Error (Check Alarm)

Thermo King Alarm Code
Description Corrective Action
KVQ Heat Error (Check Alarm)
  • KVQ valve actuation temperature is not in range within preset time.
  • Indicates:
  • Disconnected CB7A
  • Defective heat element in valve actuator
  • Inaccurate actuator temperature measurement
  • Defective relay board
  • Defective circuit between pin 4 and 6 on plug J11 (KVQ actuator requires power from both relays 2 and 3)
  • Defective cable No. 2
  • Defective controller
  • Carefully inspect actuator: If actuator is hot, check that the actuator sensor has been mounted correctly in p ins 11 and 12 on plug J15. If actuator is not hot, check resistance between pins 5 and 6 on plug J11. Resistance must be about 17 Ohms. Check voltage from pins 5 and 6 (relays 2 and 3). 
  • Check cable No. 2 between controller and relay board.