Mitsubishi Alarm Code #200 cause 3



Alarm Code #200
Model CPE52, 53, 14, 15, 15V, 16
Failure Control temperature failure
Countermeasure
<< Cause –(3) >> ( Except CPE16 units delivered after June 1999 )
Wrong setting of the Dip switch SW1- 1
< Check > ( Refer to Page F-16 )
Check the Dip switch SW1- 1 on PCB-C board.
< Action >
Set the Dip switch correctly.