Code Cd44 displays the eAutoFresh CO2 and O2 values (CO2 and O2) and CO2 and O2 limits (CO2 LIM and O2 LIM), respectively. This function code will be dashed out if not configured for eAutofresh. This function code will be dashed if CO2 sensor is not detected, and a sensor is not expected (didn’t have one previously). This function code will display “ChECK” if a CO2 sensor has not been auto-detected at the most recent power-up and was detected at a previous power-up. If “ChECK” is displayed and the ENTER key is pressed, “SEnSr” is displayed with the choices of “YES” and “no”: “YES” – sensor should be remembered as detected (present) “no” – sensor should not be remembered as being detected (not present)