Cd61 is used to force evaporator fan speed to high while temperature control is
being performed in the perishable setpoint range. When set to “On”, evaporator
fans operate in high speed regardless of any other active option that can control
evaporator fan speed.
Following a power cycle, the state of the function select code is retained at its
state prior to the power cycle. If “On”, this function select code will be set to
“OFF” when any trip start occurs or any pretrip test is initiated.
“-----” will be displayed if setpoint is in frozen range or if CnF66 is configured OFF.