Alarm Logic:
If any of the following conditions is apply
1. E107 is generated twice due to EV opening error (DECOS-3g and earlier settings)
2. E809 is generated twice due to EV opening error (DECOS-3h and later settings)
Possible Causes:
1. Refrigeration system restriction : Drier / Filter
Refer to alarm diagnosis 035 (page 5-24) and perform repairs as needed
Controller Action:
F809 Unit stopped
If any of the following conditions is apply
1. E107 is generated twice due to EV opening error (DECOS-3g and earlier settings)
2. E809 is generated twice due to EV opening error (DECOS-3h and later settings)
Possible Causes:
1. Refrigeration system restriction : Drier / Filter
- Refrigerant shortage
- ISV malfunction / Restriction at ESV outlet line capillary / Mounting position of discharge gas temperature sensor
Refer to alarm diagnosis 035 (page 5-24) and perform repairs as needed
Controller Action:
F809 Unit stopped