Mitsubishi Alarm Code #322, #324, #326, #328 cause 2



Alarm Code #322, #324, #326, #328 ( Optional Code )
Model CPE52, 53, 14, 15, 15V, 16
Failure Disconnection of Cold treatment sensor ( TCT1, TCT2, TCT3, TCT4 )
Countermeasure
<< Cause –(2) >>
Poor contact of terminals on the terminal block TB11 and TB12
< Check > ( Refer to Page F-21 )
Check looseness of the terminals ( VRF, 63, 66, 67 and 61 ) on TB11 and TB12.
< Action >
Retighten the terminals.