Mitsubishi Alarm Code #357 cause 4



Alarm Code #357
Model CPE52, 53, 14, 15, 15V, 16
Failure Current sensor for compressor ( CTM ) Low failure
Countermeasure
<< Cause -(4) >>
Offset data set error of CTM sensor
< Check > ( Refer to Page F-29 )
Check if the CTM current value displayed on the personal computer is approx. ±0.5A
range out of the measured CTM current value.
( Refer to Instruction Manual of Hand – held computer )
< Action >
Out of approx. ±0.5A range : Readjust.