Alarm Code #903
Model CPE52, 53, 14, 15, 15V, 16
Failure Pull Down time is too long
Countermeasure
<<
Cause >>
(1)
Neglected closing of container door and ventilator
(2)
Remaining frost on Evaporator coil
(3)
Compressor stop due to protector actuation and defective protector, etc.
(4)
Evaporator fan stop
(5)
Leakage of refrigerant
(6)
EEV cooling capacity control failure due to LPT shift failure, TDK shift
failure
and
EEV operation failure
(7)
EEV input limit control failure due to LPT high shift failure, CT1 or CTM high
shift failure
(8)
EEV high refrigerant pressure control failure due to HPT high shift failure
(9)
Defective PCB-C board
<
Check >
Refer
to the detail of the related failure codes and check the operation state displayed
on the personal
computer or the LCD.