Content | Alarm code | Conclusion | Possible cause | Check method |
---|---|---|---|---|
HPS check | J061 | Out of range | (1) HPS malfunction (2) High pressure transducer (HPT) malfunction (3) Gauge manifold leaking (Unit is not malfunctioning) |
(1) Check HPS (2) Compare to Gauge manifold (3) Remove Gauge manifold. |
J062 | Switch open | (1) HPS malfunction (2) High pressure transducer (HPT) malfunction (3) Gauge manifold leaking (Unit is not malfunctioning) |
(1) Check HPS (2) Compare to Gauge manifold (3) Remove Gauge manifold. |
|
J064 | High pressure does not rise. | (1) HPS malfunction (2) High pressure transducer (HPT) malfunction (3) Gauge manifold leaking (Unit is not malfunctioning) |
(1) Check HPS (2) Compare to Gauge manifold (3) Remove Gauge manifold. |
|
J065 | High pressure does not drop. | (1) HPS malfunction (2) High pressure transducer (HPT) malfunction (3) Gauge manifold leaking (Unit is not malfunctioning) |
(1) Check HPS (2) Compare to Gauge manifold (3) Remove Gauge manifold. |