| 601 | No water cooling |
|---|---|
| Description | Water-cooling fault |
| Cause | Lack of water-cooling |
| Trouble shooting |
Possible causes:
|
| Criteria | Compressor discharge temperature exceeds limit for water-cooling, 60°C (+140°F) in more than 1 hour |
601 StarCool Alarm Codes And Actions