811 | Mevap cur HI speed |
---|---|
Description | Evaporator motor high speed current fault |
Cause | Indication of defective motor or defective supply cables to motor |
Trouble shooting |
Possible causes:
|
Criteria | Evaporator fan motors have exceeded current limit at high speed. 50Hz: 1.8 – 1.9 Amp 60Hz: 2.6 – 2.1 Amp |