Carrier Controller Configuration Variables.

Read Term And Condition Before Use This Application !!!
CnF No Title Default Option
CnF02 Evaporator Fan Speed dS (Dual) SS (Single)
CnF03 Control Temperature Sensors FOUr duAL
CnF04 Enable Dehumidification On OFF
CnF08 Evaporator Motor Type 1Ph 3Ph
CnF09 Refrigerant Type r134a r744
CnF11 Defrost "Off" Selection noOFF OFF
CnF15 Enable Discharge Temperature Sensor Out In
CnF16 Enable DataCORDER On (Yes) (Not Allowed)
CnF17 Enable Discharge Pressure Sensor Out (No) In (Yes)
CnF18 Heater Type Old (Low Watt) nEW (High Watt)
CnF20 Enable Suction Pressure Sensor Out (No) Std, Full
CnF22 Economy Mode OFF Std, Full
CnF23 Enable Defrost Interval Save noSAv SAv
CnF24 Enable Long Pre-trip Test Series Auto Auto2, Auto 3
CnF25 Enable Pre-trip Data Recording rSLtS dAtA
CnF26 Heat Lockout Temperature Set to -10C Set to -5C
CnF27 Enable Suction Temperature Sensor Out In
CnF28 Enable Bulb Mode NOr bULb
CnF31 Probe Check SPEC Std
CnF32 Enable Single Evaporator Fan Option 2EF0 (Not Allowed)
CnF33 Enable Snap Freeze OFF SnAP
CnF34 Temperature Unit Display bOth F
CnF37 Electronic Chart Probe rEtUR SUPPL, bOth
CnF41 Enable Low DTT Setting Out In
CnF44 Autoslide Enable Out LO, UP
CnF45 Low Humidity Enabled Out In
CnF46 Quench/liquid Injection Valve Type nO=0=no nC=1=nc
CnF47 Vent Position OFF UP, LOW, CUStOM
CnF49 OEM Reset Option OFF 0-off,1-std, 2-spec,3-cust
CnF50 Enhanced Bulb Mode Interface 0 0-out, 1-in
CnF51 Timed Defrost Disable 0 0-out, 1-in
CnF52 Oil Return Algorithm 0 0-out, 1-in
CnF53 Water Cool Oil Return Logic 0 0-out, 1-in
CnF55 TXV Boost Relay 0 0-out, 1-in
CnF56 TXV Boost Circuit 0 0-out, 1-in
CnF57 PWM Compressor Control 0 0-out, 1-in
CnF59 Electronic Evaporator Expansion Valve 0 0-none, 1-EC, 2-KE, 3-NA
CnF61 ACT ASC Control Enable 0 0-out, 1-in
CnF62 Extended Temperature Control Enable 0 0-out, 1-in
CnF63 CCPC Pre-trip/Tripstart Default State 0 0-on, 1-off
CnF64 Enable Fan Pulsing Logic 0 0-in, 1-out
CnF66 High Speed Evaporator Fan Option 0 0-off, 1-on
CnF67 Air Heaters 0 0-out, 1-in

Note:
Configuration numbers not listed are not used in this application. These items may appear when loading configuration software to the controller but changes will not be recognized by the controller programming.

Last Manual Reference & Combine: 69NT40-561-001 To 199