Saturday, February 28, 2009

Basic Motor Theory 1



Basic Motor Theory


Introduction


It has been said that if the Ancient Romans, with their advanced civilization and knowledge of the sciences, had been able to develop a steam motor, the course of history would have been much different. The development of the electric motor in modern times has indicated the truth in this theory. The development of the electric motor has given us the most efficient and effective means to do work known to man. Because of the electric motor we have been able to greatly reduce the painstaking toil of man's survival and have been able to build a civilization which is now reaching to the stars. The electric motor is a simple device in principle. It converts electric energy into mechanical energy. Over the years, electric motors have changed substantially in design, however the basic principles have remained the same. In this section of the Action Guide we will discuss these basic motor principles. We will discuss the phenomena of magnetism, AC current and basic motor operation.

Magnetism


Now, before we discuss basic motor operation a short review of magnetism might be helpful to many of us. We all know that a permanent magnet will attract and hold metal objects when the object is near or in contact with the magnet. The permanent magnet is able to do this because of its inherent magnetic force which is referred to as a "magnetic field". In Figure 1 , the magnetic field of two permanent magnets are represented by "lines of flux". These lines of flux help us to visualize the magnetic field of any magnet even though they only represent an invisible phenomena. The number of lines of flux vary from one magnetic field to another. The stronger the magnetic field, the greater the number of lines of flux which are drawn to represent the magnetic field. The lines of flux are drawn with a direction indicated since we should visualize these lines and the magnetic field they represent as having a distinct movement from a N-pole to a S-pole as shown in Figure 1. Another but similar type of magnetic field is produced around an electrical conductor when an electric current is passed through the conductor as shown in Figure 2-a. These lines of flux define the magnetic field and are in the form of concentric circles around the wire. Some of you may remember the old "Left Hand Rule" as shown in Figure 2-b. The rule states that if you point the thumb of your left hand in the direction of the current, your fingers will point in the direction of the magnetic field.

Figure 1 - The lines of flux of a magnetic field travel from the N-pole to the S-pole.


Figure 2 - The flow of electrical current in a conductor sets up concentric lines of magnetic flux around the conductor.

Figure 3 - The magnetic lines around a current carrying conductor leave from the N-pole and re-enter at the S-pole.
When the wire is shaped into a coil as shown in Figure 3, all the individual flux lines produced by each section of wire join together to form one large magnetic field around the total coil. As with the permanent magnet, these flux lines leave the north of the coil and re-enter the coil at its south pole. The magnetic field of a wire coil is much greater and more localized than the magnetic field around the plain conductor before being formed into a coil. This magnetic field around the coil can be strengthened even more by placing a core of iron or similar metal in the center of the core. The metal core presents less resistance to the lines of flux than the air, thereby causing the field strength to increase. (This is exactly how a stator coil is made; a coil of wire with a steel core.) The advantage of a magnetic field which is produced by a current carrying coil of wire is that when the current is reversed in direction the poles of the magnetic field will switch positions since the lines of flux have changed direction. This phenomenon is illustrated in Figure 4. Without this magnetic phenomenon existing, the AC motor as we know it today would not exist.

Figure 4 - The poles of an electro-magnetic coil change when the direction of current flow changes.


Magnetic Propulsion Within A Motor


The basic principle of all motors can easily be shown using two electromagnets and a permanent magnet. Current is passed through coil no. 1 in such a direction that a north pole is established and through coil no. 2 in such a direction that a south pole is established. A permanent magnet with a north and south pole is the moving part of this simple motor. In Figure 5-a the north pole of the permanent magnet is opposite the north pole of the electromagnet. Similarly, the south poles are opposite each other. Like magnetic poles repel each other, causing the movable permanent magnet to begin to turn. After it turns part way around, the force of attraction between the unlike poles becomes strong enough to keep the permanent magnet rotating. The rotating magnet continues to turn until the unlike poles are lined up. At this point the rotor would normally stop because of the attraction between the unlike poles. (Figure 5-b)

Figure 5

If, however, the direction of currents in the electromagnetic coils was suddenly reversed, thereby reversing the polarity of the two coils, then the poles would again be opposites and repel each other. (Figure 5-c). The movable permanent magnet would then continue to rotate. If the current direction in the electromagnetic coils was changed every time the magnet turned 180 degrees or halfway around,then the magnet would continue to rotate. This simple device is a motor in its simplest form. An actual motor is more complex than the simple device shown above, but the principle is the same.

AC Current


How is the current reversed in the coil so as to change the coils polarity, you ask. Well, as you probably know, the difference between DC and AC is that with DC the current flows in only one direction while with AC the direction of current flow changes periodically. In the case of common AC that is used throughout most of the United States, the current flow changes direction 120 times every second. This current is referred to as "60 cycle AC" or "60 Hertz AC" in honor of Mr. Hertz who first conceived the AC current concept. Another characteristic of current flow is that it can vary in quantity. We can have a 5 amp, 10 amp or 100 amp flow for instance. With pure DC, this means that the current flow is actually 5,10, or 100 amps on a continuous basis. We can visualize this on a simple time-current graph by a straight line as shown in Figure 6.

Figure 6 - Visualization of DC

But with AC it is different. As you can well imagine, it would be rather difficult for the current to be flowing at say 100 amps in a positive direction one moment and then at the next moment be flowing at an equal intensity in the negative direction. Instead, as the current is getting ready to change directions, it first tapers off until it reaches zero flow and then gradually builds up in the other direction. See Figure 7. Note that the maximum current flow (the peaks of the line) in each direction is more than the specified value (100 amps in this case). Therefore, the specified value is given as an average. It is actually called a "root mean square" value, but don't worry about remembering this because it is of no importance to us at this time. What is important in our study of motors, is to realize that the strength of the magnetic field produced by an AC electro-magnetic coil increases and decreases with the increase and decrease of this alternating current flow.

Figure 7 - Visualization of AC.


Basic AC Motor Operation


An AC motor has two basic electrical parts: a "stator" and a "rotor" as shown in Figure 8. The stator is in the stationary electrical component. It consists of a group of individual electro-magnets arranged in such a way that they form a hollow cylinder, with one pole of each magnet facing toward the center of the group. The term, "stator" is derived from the word stationary. The stator then is the stationary part of the motor. The rotor is the rotating electrical component. It also consists of a group of electro-magnets arranged around a cylinder, with the poles facing toward the stator poles. The rotor, obviously, is located inside the stator and is mounted on the motor's shaft. The term "rotor" is derived from the word rotating. The rotor then is the rotating part of the motor. The objective of these motor components is to make the rotor rotate which in turn will rotate the motor shaft. This rotation will occur because of the previously discussed magnetic phenomenon that unlike magnetic poles attract each other and like poles repel. If we progressively change the polarity of the stator poles in such a way that their combined magnetic field rotates, then the rotor will follow and rotate with the magnetic field of the stator.

Figure 8 - Basic electrical components of an AC motor.

This "rotating magnetic fields of the stator can be better understood by examining Figure 9. As shown, the stator has six magnetic poles and the rotor has two poles. At time 1, stator poles A-1 and C-2 are north poles and the opposite poles, A-2 and C-1, are south poles. The S-pole of the rotor is attracted by the two N-poles of the stator and the N-pole of the rotor is attracted by the two south poles of the stator. At time 2, the polarity of the stator poles is changed so that now C-2 and B-1 and N-poles and C-1 and B-2 are S-poles. The rotor then is forced to rotate 60 degrees to line up with the stator poles as shown. At time 3, B-1 and A-2 are N. At time 4, A-2 and C-1 are N. As each change is made, the poles of the rotor are attracted by the opposite poles on the stator. Thus, as the magnetic field of the stator rotates, the rotor is forced to rotate with it.

Figure 9 - The rotating magnetic field of an AC motor.

One way to produce a rotating magnetic field in the stator of an AC motor is to use a three-phase power supply for the stator coils. What, you may ask, is three-phase power? The answer to that question can be better understood if we first examine single-phase power. Figure 7 is the visualization of single-phase power. The associated AC generator is producing just one flow of electrical current whose direction and intensity varies as indicated by the single solid line on the graph. From time 0 to time 3, current is flowing in the conductor in the positive direction. From time 3 to time 6, current is flowing in the negative. At any one time, the current is only flowing in one direction. But some generators produce three separate current flows (phases) all superimposed on the same circuit. This is referred to as three-phase power. At any one instant, however, the direction and intensity of each separate current flow are not the same as the other phases. This is illustrated in Figure 10. The three separate phases (current flows) are labeled A, B and C. At time 1, phase A is at zero amps, phase B is near its maximum amperage and flowing in the positive direction, and phase C is near to its maximum amperage but flowing in the negative direction. At time 2, the amperage of phase A is increasing and flow is positive, the amperage of phase B is decreasing and its flow is still negative, and phase C has dropped to zero amps. A complete cycle (from zero to maximum in one direction, to zero and to maximum in the other direction, and back to zero) takes one complete revolution of the generator. Therefore, a complete cycle, is said to have 360 electrical degrees. In examining Figure 10, we see that each phase is displaced 120 degrees from the other two phases. Therefore, we say they are 120 degrees out of phase.

Figure 10 - The pattern of the separate phases of three-phase power.

To produce a rotating magnetic field in the stator of a three-phase AC motor, all that needs to be done is wind the stator coils properly and connect the power supply leads correctly. The connection for a 6 pole stator is shown in Figure 11. Each phase of the three-phase power supply is connected to opposite poles and the associated coils are wound in the same direction. As you will recall from Figure 4, the polarity of the poles of an electro-magnet are determined by the direction of the current flow through the coil. Therefore, if two opposite stator electro-magnets are wound in the same direction, the polarity of the facing poles must be opposite. Therefore, when pole A1 is N, pole A2 is S. When pole B1 is N, B2 is S and so forth.

Figure 11 - Method of connecting three-phase power to a six-pole stator.

Figure 12 shows how the rotating magnetic field is produced. At time1, the current flow in the phase "A" poles is positive and pole A-1 is N. The current flow in the phase "C" poles is negative, making C-2 a N-pole and C-1 is S. There is no current flow in phase "B", so these poles are not magnetized. At time 2, the phases have shifted 60 degrees, making poles C-2 and B-1 both N and C-1 and B-2 both S. Thus, as the phases shift their current flow, the resultant N and S poles move clockwise around the stator, producing a rotating magnetic field. The rotor acts like a bar magnet, being pulled along by the rotating magnetic field.

Figure 12 - How three-phase power produces a rotating magnetic field.

Up to this point not much has been said about the rotor. In the previous examples, it has been assumed the rotor poles were wound with coils, just as the stator poles, and supplied with DC to create fixed polarity poles. This, by the way, is exactly how a synchronous AC motor works. However, most AC motors being used today are not synchronous motors. Instead, so-called "induction" motors are the workhorses of industry. So how is an induction motor different? The big difference is the manner in which current is supplied to the rotor. This is no external power supply. As you might imagine from the motor's name, an induction technique is used instead. Induction is another characteristic of magnetism. It is a natural phenomena which occurs when a conductor (aluminum bars in the case of a rotor, see Figure 13) is moved through an existing magnetic field or when a magnetic field is moved past a conductor. In either case, the relative motion of the two causes an electric current to flow in the conductor. This is referred to as "induced" current flow. In other words, in an induction motor the current flow in the rotor is not caused by any direct connection of the conductors to a voltage source, but rather by the influence of the rotor conductors cutting across the lines of flux produced by the stator magnetic fields. The induced current which is produced in the rotor results in a magnetic field around the rotor conductors as shown in Figure 14. This magnetic field around each rotor conductor will cause each rotor conductor to act like the permanent magnet in the Figure 9 example. As the magnetic field of the stator rotates, due to the effect of the three-phase AC power supply, the induced magnetic field of the rotor will be attracted and will follow the rotation. The rotor is connected to the motor shaft, so the shaft will rotate and drive the connection load. That's how a motor works! Simple, was it not?

Figure 13 - Construction of an AC induction motor's rotor.


Figure 14 - How voltage is induced in the rotor, resulting in current flow in the rotor conductors.



DC Motor Theory


Preface
The intent of this paper is to provide one with an understanding of DC Motors in order that they can be applied with confidence. This paper contains basic information and specific information that applies to Reliance Medium HP and Large HP DC Motors. Due to the nature of Baldor Systems business, emphasis has been placed on the Large DC motor product line.

Section 1: Dynamo Development

The first generators and motors were called dynamos or dynamoelertric machines. Dynamo is from the Greek word dynamis which means power. Webster defines dynamoelectric as "relating to the conversion of mechanical energy into electrical energy or vice versa". The word motor is from the Latin word motus which means one that imparts motion or prime mover. The dynamo was the result of the efforts of several people, in different countries, in the mid-nineteenth century, to make electricity work for them.
Definitions
Dynamo: From the Greek word dynamis, which means power
Dynamoelectric: Relating to the conversion by induction of mechanical energy into electrical energy or vice versa
Dynamoelectric machine: A dynamo or generator
Motor: From the Latin word motus, one that imparts motion, prime mover. A device that changes electrical energy into mechanical energy.
Generator: A device that changes mechanical energy into electrical energy. Although the terms AC and DC generator are in common usage, a generator is normally considered to be a device that provides DC current.
Alternator: A device that changes mechanical energy into an alternating current electrical energy, an AC generator.
Landmarks Of Electric Motor Development
1820 The discovery of electromagnetism Hans Christian Oersted, Danish
1827 The statement of the law of electric conduction, Ohm's law George S. Ohm, German
1830 The discovery of electromagnetic induction Joseph Henry, American
1831 The discovery of electromagnetic induction Michael Faraday, English

The first practical dynamo, about 1867

Section 2: Electric Motor And Generator Basics

Electrodynamic Principles

Faraday's Law
In order that current can be obtained from an electric circuit, an electromotive force (voltage) must be established and maintained between the two ends of the circuit. This electromotive force may be established in several ways, one of which is by means of an electromagnetic generator.

Michael Faraday discovered that an electric potential can be established between the ends of a conductor in the following three ways:
  • By a conductor moving or cutting across a stationary magnetic field. (DC Generator)
  • By a moving magnetic field cutting across a stationary conductor. (AC Generator)
  • By a change in the number of magnetic lines enclosed by a stationary loop or coil. (Transformer)

Faraday's law states that, "the EMF (electromotive force) induced between the ends of a loop or coil is proportional to the rate of change of magnetic flux enclosed by the coil; or the EMF induced between the ends of a bar conductor is proportional to the time rate at which magnetic flux is cut by the conductor."
This law emphasizes rate of change or rate or flux cutting rather than density or extent of magnetic field.
Lenz's Law
Lenz's Law states that, "A change in the magnetic flux passing through or linking with, a loop or coil causes EMF to be induced in a direction to oppose any change in circuit conditions, this opposition being produced magnetically when current flows in response to the induced EMF."

Whenever there is a change in current in a magnetizing coil, which works to change the flux in the coil, a voltage is induced which tends to prevent the change. Thus, if we attempt to diminish the current flowing in a magnetizing coil, a voltage will be developed that will tend to keep the current unchanged. Likewise, if we attempt to establish a current in a magnetizing coil, a voltage will be developed that will tend to keep the current from increasing.

Generator Basic Principles

Energy Conversion
To produce voltage, it is necessary to move a conductor through a magnetic field as stated above. Mechanical energy is required to provide motion to this conductor. With the field energy remaining constant, the conductor is changing mechanical energy into electrical energy.

Voltage Generation
There is a definite relationship between the direction of the magnetic flux, the direction of motion of the conductor and the direction of the induced EMF. Figure 1 shows the motion of the conductor perpendicular to the magnetic field. The voltage and current output are perpendicular to both the motion of the conductor and the magnetic field.

Figure 1.
Voltage Generation
To illustrate this with Fleming's right hand rule, the thumb and first two fingers of the right hand are extended at right angles to one another, the thumb will indicate the direction of motion of the conductor, the forefinger will indicate the direction of the magnetic field, and the middle finger will indicate the direction of voltage or current.
Applying this rule, one can see that the current will reverse if the motion of the conductor changes from down to up. This is true even though the magnetic field does not change position. Therefore, the rotating coil in Figure 2 will produce a voltage which is continually changing direction.
Figure 2.
Revolving Coil in a Magnetic Field



  1. Voltage Induced in Conductor Moving Through a Magnetic Field
  2. Revolving Coil in a Magnetic Field
The coil in position AB, in figure 2, encloses the maximum amount of flux. The flux decreases as the coil moves toward position CD and becomes zero at CD, since the plane of the coil is parallel to the magnetic field. Then the flux increases in the opposite direction, reaching a negative maximum at BA and diminishing again to zero at DC. The flux reverses and increases again in the original direction to reach a maximum at AB.
Although the flux is maximum at positions AB and BA and zero at positions CD and DC, the induced EMF will be maximum at positions CD and DC and zero at positions AB and BA. This is true because the EMF depends upon the rate of change of flux or rate of cutting flux lines and not upon the quantity enclosed.
If the coil in Figure 2 were rotated at a constant speed in a uniform magnetic field, a sine wave of voltage would be obtained. This is shown in Figure 3 where both the amount of flux enclosed and the EMF induced are plotted against time.
Figure 3.
Voltage Sine Wave Produced by rotation of a coil at constant speed in a uniform magnetic field.
Value of Generated Voltage
The EMF at any instant of time is proportional to the number of turns in the coil times rate of change of flux. The C.G.S. (centimeter gram second) unit of EMF known as the abvolt is defined as that value induced, in a coil of one turn, when the flux linking with the coil is changing at the rate of one line or Maxwell per second; or as that value induced when magnetic flux is being cut by the conductor at the rate of one line per second. A volt is equal to 108 abvolts or an abvolt is equal to 10
-8 volts. Therefore, the instantaneous value of voltage is expressed as:
e = N x (d / dt) x 10-8
where:
e = voltage
N = the number of turns
d / dt = the rate of change of flux
This equation can be further developed to obtain the voltage for movement of a conductor at constant velocity through a uniform magnetic field:
E = N B v sin x 10-8
where:
E = voltage
N = number of turns
B = flux density in lines per square inch
= length of the conductor in inches
v = velocity in inches per second
= the angle between the conductor and flux field
If the conductor moves directly across the field at right angles to it, then = 90° and sin = 1. The equation then becomes:
E = N B v x 10-8
It should be noted that this equation is a special form of the original equation and is not applicable in all cases.

MOTOR BASIC PRINCIPLES

Energy Conversion
As stated above, mechanical energy is changed into electrical energy by movement of conductor through a magnetic field. The converse of this is also true. If electrical energy is supplied to a conductor lying normal to a magnetic field, resulting in current flow in the conductor, a mechanical force and thus mechanical energy will be produced.

Producing Mechanical Force
As in the generator, the motor has a definite relationship between the direction of the magnetic flux, the direction of motion of the conductor or force, and the direction of the applied voltage or current.

Since the motor is the reverse of the generator, Fleming's left hand rule can be used. If the thumb and first two fingers of the left hand are extended at right angles to one another, the thumb will indicate the direction of motion, the forefinger will indicate the direction of the magnetic field, and the middle finger will indicate the direction of current. In either the motor or generator, if the directions of any two factors are known, the third can be easily determined.
Value of Mechanical Force
The force exerted upon a current carrying conductor is dependent upon the density of the magnetic field, the length of conductor, and the value of current flowing in the conductor. Assuming that the conductor is located at right angles to the magnetic field, the force developed can be expressed as follows:

F = (B I) / 10
where:
F = force in dynes
B = flux density in lines per square centimeter
= length of the conductor in centimeters
I = current in amperes.
At the same time torque is being produced, the conductors are moving in a magnetic field and generating a voltage. This voltage is in opposition to the voltage that causes current flow through the conductor and is referred to as a countervoltage or back EMF. The value of current flowing through the armature is dependent upon the difference between the applied voltage and the countervoltage.
Sample Calculations
Generator
Given:
N = 60 turns
B = 40,000 lines per square inch
= 3.0 inches
v = 600 inches per second
Find:
E = voltage
E = 60 x 40,000 x 3 x 600 x 10-8 = 43.2 volts
Motor
Given:
B = 6,000 lines per square centimeter
= 10 Centimeters
I = 50 amps
Find:
F = force
F = (6,000 x 10 x 50) / 10 = 300,000 dynes
Newtons = Pounds x 4.44823
Dynes = Newtons x 100,000


DC Machines, Principles Of Operation
Generator
In a generator, moving a conductor through a stationary magnetic field generates voltage. If a coil is rotated through a magnetic field as shown in Figure 4, an alternating voltage will be produced. To make this voltage available to a stationary external circuit, two slip rings and brushes must be provided. For the external circuit to produce DC voltage, it is necessary to reverse the polarity of the external leads at the same time the voltage in the coil is reversed. This is accomplished by segmenting a slip ring to form what is called a commutator. An elementary two segment commutator is illustrated in Figure 5. This single coil, two piece commutator will yield an unidirectional but pulsating voltage as shown in Figure 6. However, when a large number of commutator segments or bars is used, the resulting voltage will be more uniform as shown in Figure 7.
Figure 4.
Brushes and slip rings provide AC voltage

Figure 5.
Brushes and Commutator provides DC voltage


Figure 6.
Unidirectional, Pulsating Voltage


Figure 7.
Uniform DC Voltage

As stated above, the generated voltage in a single conductor is:
E = N B v x 10-8
where:
B = flux density in lines per square inch
= length of the conductor in inches
v = velocity in inches per second
This equation can be developed to the following equation for DC machines:
E = (Z / paths) x x poles x (rpm / 60) x 10-8
where:
Z = total number of conductors
= flux per pole in lines
This equation represents the average voltage. For a given machine, it can be reduced to:
E = K1 S
where:
= flux per pole
S = speed in rpm
K1 = all other factors
Motor
As stated previously, if current is supplied to a conductor in a magnetic field, a force will be produced. The force developed in a single conductor is:
F = (B I) / 10
where:
F = force in dynes
B = flux density in lines per square centimeter
= length of the conductor in centimeters
I = current in amperes
This equation can be developed to the following for DC motors:
T = 11.73 x (Z / paths) x x poles x IA x 10-10
where:
T = torque in ft-lb
Z = total number of conductors
= flux per pole in lines
I = current in amperes
For a given machine, this can be reduced to:
T = K2 IA
where:
= flux per pole in lines
IA = current in amperes
K2 = all other factors
K2 is not the same as the K1 for voltage. The above torque is not the output torque of the shaft, but rather the total torque developed by the armature. Part of this total torque is needed to overcome the inertia of the armature itself.

The horsepower output of any motor can be expressed as:
HP = T x N / C
where:
T = output torque in ft-lb
N = speed in rpm
C = the constant 5252

DC General Construction

A typical DC generator or motor usually consists of: An armature core, an air gap, poles, and a yoke which form the magnetic circuit; an armature winding, a field winding, brushes and a commutator which form the electric circuit; and a frame, end bells, bearings, brush supports and a shaft which provide the mechanical support. See figure 8.

Figure 8.
Four Pole DC Motor

Armature Core or Stack
The armature stack is made up thin magnetic steel laminations stamped from sheet steel with a blanking die. Slots are punched in the lamination with a slot die. Sometimes these two operations are done as one. The laminations are welded, riveted, bolted or bonded together.

Armature Winding
The armature winding is the winding, which fits in the armature slots and is eventually connected to the commutator. It either generates or receives the voltage depending on whether the unit is a generator or motor. The armature winding usually consists of copper wire, either round or rectangular and is insulated from the armature stack.

Field Poles
The pole cores can be made from solid steel castings or from laminations. At the air gap, the pole usually fans out into what is known as a pole head or pole shoe. This is done to reduce the reluctance of the air gap. Normally the field coils are formed and placed on the pole cores and then the whole assembly is mounted to the yoke.

Field Coils
The field coils are those windings, which are located on the poles and set up the magnetic fields in the machine. They also usually consist of copper wire are insulated from the poles. The field coils may be either shunt windings (in parallel with the armature winding) or series windings (in series with the armature winding) or a combination of both.

Yoke
The yoke is a circular steel ring, which supports the field, poles mechanically and provides the necessary magnetic path between the pole. The yoke can be solid or laminated. In many DC machines, the yoke also serves as the frame.

Commutator
The commutator is the mechanical rectifier, which changes the AC voltage of the rotating conductors to DC voltage. It consists of a number of segments normally equal to the number of slots. The segments or commutator bars are made of silver bearing copper and are separated from each other by mica insulation.

Brushes and Brush Holders
Brushes conduct the current from the commutator to the external circuit. There are many types of brushes. A brush holder is usually a metal box that is rectangular in shape. The brush holder has a spring that holds the brush in contact with the commutator. Each brush usually has a flexible copper shunt or pigtail, which extends to the lead wires. Often, the entire brush assembly is insulated from the frame and is made movable as a unit about the commutator to allow for adjustment.

Interpoles
Interpoles are similar to the main field poles and located on the yoke between the main field poles. They have windings in series with the armature winding. Interpoles have the function of reducing the armature reaction effect in the commutating zone. They eliminate the need to shift the brush assembly.

Frame, End Bells, Shaft, and Bearings
The frame and end bells are usually steel, aluminum or magnesium castings used to enclose and support the basic machine parts. The armature is mounted on a steel shaft, which is supported between two bearings. The bearings are either sleeve, ball or roller type. They are normally lubricated by grease or oil.

Back End, Front End
The load end of the motor is the Back End. The opposite load end, most often the commutator end, is the Front End of the motor.


Armature Windings

Gramme Ring Winding
The old Gramme Ring type winding, now obsolete, is shown in Figure 9 and its equivalent circuit in Figure 10. It can be seen that there are an equal number of voltage-generating conductors on each side of the armature and the conductor voltages are additive from bottom to top on each side. There are two paths between the positive and negative brushes and the voltage per path is the generated voltage of the machine. Each path provides half of the current output.

Figure 9.
Two Pole Gramme Ring Winding

Figure 10.
Equivalent Circuit, Two Pole Gramme Ring Winding
Drum Winding
The Drum type winding is made of coils, one of which is illustrated in Figure 11. The straight portions of the coil are the parts rotating through the magnetic field in which the voltage is induced. Therefore, each single coil has two conductors. This has the advantage over the Gramme Ring winding where only one side of each coil is used as an active conductor. There are two classes of drum windings depending upon how the coils are connected to the commutator.

Figure 11.
Drum Type Winding Coil
Lap Winding
When the end connections of the coils are brought to adjacent bars as shown in Figure 12, a lap or parallel winding is formed. In this type winding, there are as many paths through the armature as there are poles on the machine. Therefore, to obtain full use of this type winding, there must be as many brushes as there are poles, alternate brushes being positive and negative. Any winding can be illustrated in one of two forms, the circular form or the development form. A simplex lap winding is shown in Figure 13 (circular form) and Figure 14 (development form.) In this particular circular form, the flux cutting portions of the conductors are shown as straight lines radiating from the center and are numbered for convenience in connecting them to the commutator which is in the center of the diagram. The outermost connecting lines represent the end connections on the back of the armature and the inner connecting lines represent the connections on the front or commutator end of the armature. The development form of winding represents the armature as if it were split open and rolled out flat. It is somewhat simpler to understand but the continuity of the winding is broken. The lap winding is best suited for low voltage, high current ratings because of the number of parallel paths.

Figure 12.
Lap Winding connected to commutator bars

Figure 13.
Simplex Lap Winding, Circular Form


Figure 14.
Simplex Lap Winding, Development Form

Wave Winding
When the end connections of the coils are spread apart as shown in Figure 15 a wave or series winding is formed. In a wave winding there are only two paths regardless of the number of poles. Therefore, this type winding requires only two brushes but can use as many brushes as poles. The simplex wave winding in Figure 16 (circular) and Figure 17 (development) shows that the connections to the armature do not lap back toward the coil but progress forward. The coil voltages are cumulative but it is necessary to travel several times around the armature and to traverse half the total winding in order to trace the path between the positive and negative brush. The wave winding is best suited for high voltage low current ratings since it has only two paths.

Figure 15.
Wave Winding connected to commutator bars

Figure 16.
Simplex Wave Winding, Circular Form


Figure 17.
Simplex Wave Winding, Development Form

Slots and Coils
The number and size of slots depend upon the generator or motor requirements. The slot has to be large enough to hold the correct number of conductors but at the same time, the tooth has to be large enough to pass the necessary magnetic flux. Normally, in a simple winding, there are as many coils as there are slots. This means that each slot contains two coil sides, one side of each coil being at the top of a slot and the other at the bottom of a slot. Each coil may consist of one or more turns depending on the applied or generated voltage of the unit. A typical arrangement of coil sides and slots is shown in Figure 18. Solid lines represent the front end connections to the commutator and dotted lines represent the back end connections.

Slot Pitch
Slot pitch refers to the number of slots spanned by each coil. For example, in Figure 18, the top of coil in slot 1 has its bottom in slot 4, therefore, the slot pitch is 1-4 or 3. Since the top of the coil is directly under the north pole and the bottom is directly under the south pole, the winding is known as a full pitch winding. In many cases, for various reasons, the pitch is reduced to less than full pitch. For example, if the coils in Figure 6 spanned 2 slots instead of three, the winding would become a two-thirds pitch winding.

Figure 18.
Coil Sides in Armature Slots

Field Windings

The field windings provide the excitation necessary to set up the magnetic fields in the machine. There are various types of field windings that can be used in the generator or motor circuit. In addition to the following field winding types, permanent magnet fields are used on some smaller DC products. See Figure 19 for winding types.
Shunt Wound - DC Operation
Typical Speed - Torque Curve
Shunt wound motors, with the armature shunted across the field, offer relatively flat speed-torque characteristics. Combined with inherently controlled no-load speed, this provides good speed regulation over wide load ranges. While the starting torque is comparatively lower than the other DC winding types, shunt wound motors offer simplified control for reversing service.



Compound Wound - DC Operation
Typical Speed - Torque Curve
Compound wound (stabilized shunt) motors utilize a field winding in series with the armature in addition to the shunt field to obtain a compromise in performance between a series and shunt type motor. This type offers a combination of good starting torque and speed stability. Standard compounding is about 12%. Heavier compounding of up to 40 to 50% can be supplied for special high starting torque applications, such as hoists and cranes.



Series Wound - DC Operation
Typical Speed - Torque Curve
Series wound motors have the armature connected in series with the field. While it offers very high starting torque and good torque output per ampere, the series motor has poor speed regulation. Speed of DC series motors is generally limited to 5000 rpm and below. Series motors should be avoided in applications where they are likely to lose there load because of their tendency to "run away" under no-load conditions. These are generally used on crane and hoist applications.



Permanent Magnet - DC Operation
Typical Speed - Torque Curve
Permanent magnet motors have no wound field and a conventional wound armature with commutator and brushes. This motor has excellent starting torques, with speed regulation not as good as compound motors. However, the speed regulation can be improved with various designs, with corresponding lower rated torques for a given frame. Because of permanent field, motor losses are less with better operating efficiencies. These motors can be dynamically braked and reversed at some low armature voltage (10%) but should not be plug reversed with full armature voltage. Reversing current can be no higher than the locked armature current.
Figure 19.
Field Windings

Separately Excited Winding
When the field is connected to an external power source, it is a separately excited field.

Straight Shunt Winding
This winding is connected in parallel with the armature. Shunt windings usually consists of a large number of turns of small size wire. This is a good winding for reversing applications since it provides the same amount of torque in both directions. The torque/ current curve is non-linear above full load. Shunt wound motors often have a rising speed characteristic with increased load.

Series Winding
This winding is connected in series with the armature. A series winding usually consists of a small number of turns of large size wire. With this winding, the motor can produce high starting and overload torque. This design is not used for applications with light loads or no load conditions.

Compound Winding
This winding consists of a shunt winding and a series winding. This is also known as compound excitation. The series winding can be designed as a starting series only or as a start and run series.

Stabilized Shunt Winding
Like the compound winding, this winding consists of a shunt winding and a series winding. The series or stabilizing winding has a fewer number of turns than the series winding in a compound wound machine. A stabilizing winding is used to assures a speed droop with overload. It also adds to the torque in one direction of operation and subtracts from torque in the reverse direction of operation and in regeneration.

Shunt Compensated Winding
Shunt compensated motors have a shunt winding and a pole face series winding made up of large conductors placed in slots in the face of the main field poles. The direction of current in the compensating windings is the opposite of the current in the armature conductors passing under the poles. The flux produced by the compensating windings neutralizes the flux of the armature conductors passing under the poles so that distortion of air gap flux is minimized. Shunt compensated motors maintain constant or set speed well at all loads, no load through overload. Unlike the stabilized shunt winding, the pole face winding adds to torque in both the forward and reverse direction of rotation. Shunt compensated windings, due to cost and difficulty of construction, are provided on large motors only, usually 840 frames and larger.


Commutation

The maximum voltage from an armature winding can be obtained when the brushes are in contact with those conductors, which are midway between the poles. This will result in the greatest possible number of conductors cutting the magnetic lines in one direction between a positive and negative brush. This brush position is known as the no load neutral position of the brushes. The current in a given armature coil reverses in direction as the coil sides move from one pole to another of opposite polarity, whereas the function of the commutator is to keep the current unidirectional. This reversal of current is known as commutation. The commutator acts as a switch to keep the current flowing in one direction. However, the fast rate of change in direction of the current in any given coil induces an appreciable voltage in that coil which tends to keep the current flowing in the original direction. Therefore, the current reversal is delayed causing an accelerated rate of change near the end of the commutation period. This results in an arc if the reversal is not completed before the brush breaks contact with the coil involved. Any arcing is detrimental to the operation of the machine and must be counteracted.
Armature Reaction
Since the armature conductors carry current they set up a magnetic field which distorts or opposes the main field. This is called armature reaction and is a function of the amount of load present. Figure 21 shows the MMF and flux wave shapes due to the armature reaction only; and Figure 22 shows the combined effect of both. It can be seen that armature reaction causes the flux to shift, thus tending to saturate one pole tip. If this effect is appreciable, it can be detrimental to the satisfactory performance of the machine. If severe enough, it may result in a flashover, which is the progressive arcing over successive bars until the arc extends from positive to negative brush, thus short circuiting the machine terminals.


Figure 20.
MMF and Flux Wave Shape due to Main Field only


Figure 21.
MMF and Flux Wave Shape due to Armature Reaction only


Figure 22.
Flux Wave Shape, combined effect

Brush Shifting
One method of reducing the arcing due to non-linear commutation is to shift the brushes away from the geometrical neutral position. Then commutation will occur when the applicable coil is under the influence of a weak magnetic field that will generate a voltage in the coil, which opposes the induced voltage due to current change. Therefore, this new voltage will assist rather than hinder the current reversal. In a generator, it is necessary to shift the brushes forward in the direction of rotation for good commutation. This is true because the current flow through the conductors is in the same direction as the voltage and, it commutation is delayed until the coil sides are under the next pole, it will be assisted by the current reversing voltage. In a motor, it is necessary to shift the brushes against the direction of rotation because current flow is in opposition to the induced voltage. The amount of shift necessary depends on the load so a given shift will not be satisfactory for all loads. One effect of shifting brushes is that a demagnetization component of armature reaction is introduced. In other words, when the brushes are shifted, the armature reaction will not only distort the main field flux but it will also directly oppose the main field. This will result in a reduction of the field flux. Another effect is that if the brushes are shifted far enough, it is possible to reduce the number of effective turns because there will be voltages in opposition to each other between two brushes.

In generators the demagnetization component of armature reaction would be detrimental because there will be a decrease in generated voltage with increase in load. However, in a motor, the effect would be beneficial because the speed would tend to remain constant.
Interpoles
Another method to combat the induced voltage caused by current reversal is the use of interpoles. The interpoles are located at the geometric neutral points midway between the main poles and provide reversing magnetic field of proper strength and polarity. They eliminate the need for brush shifting and, because of this, the demagnetization effect of armature reaction is eliminated. The interpole must have sufficient strength to overcome the armature reaction and provide a reversing field, therefore, it is connected in series with the armature winding. When the armature current is increased in the same proportion. In a generator, the interpole must have the same polarity as the next pole in the direction of rotation while in a motor the interpole must have the same polarity as the last pole.


Generator Characteristics

No Load Saturation Curve
A typical no load saturation curve is shown in Figure 23. This is similar to the magnetization curve mentioned previously except that it represents the entire magnetic circuit of a machine rather than one particular magnetic material. Also, it has generator output voltage plotted against field current rather than flux density against magnetizing force. This can be done since generator voltage is directly proportional to the field flux and the number of turns is fixed. There is a different saturation curve for each speed. The lower straight line portion of the curve represents the air gap because the magnetic parts are not saturated. When the magnetic parts start to saturate, the curve bends over until complete saturation is reached. Then the curve becomes a straight line again.


Figure 23.
No Load Saturation Curve


Figure 23.1
No Load Saturation Curve

Figure 23.2
No Load Saturation Curve
Generator Build Up
Generator build up usually refers to the gradual rise in voltage at the armature terminals when the machine is self-excited and operated at normal speed. This is illustrated in Figure 25 by referring to the field resistance line which shows how the field current varies as field voltage is varied. The slope of this line is the field resistance at a constant temperature. The voltage rise starts with the residual magnetism of the field iron. This provides a small voltage output E
1 that is fed back to the field as 1. 1 increases the flux providing a slightly larger voltage, E2 . E2 causes 2 to flow. This process continues until the machine starts to saturate and stops at the point where the field resistance line intersects the saturation curve. If the speed of the machine is reduced so that the saturation curve becomes tangent to field resistance curve, the voltage will not build up. This is known as the critical speed. Also, at any given speed, if the field resistance is increased by addition of external resistance, a critical resistance can be reached.

Figure 25.
DC Motor Curves

Voltage Output The voltage equation has been expressed as:
E = K1 S.
However, this is the generated voltage and part of it must be used to overcome the IR drops in the machine, which are caused by the resistance's of the armature, series field, interpoles, brushes, etc. If these resistance's are combined together and called armature resistance, then the voltage output at the generator terminals can be expressed as:
V = E - Ia Ra - K1 S - Ia Ra
where:
E = generated voltage
Ia = armature current
Ra = armature circuit resistance
K1 = machine constants
= flux per pole
S = speed.
External Characteristics
The curve showing the relationship between output voltage and output current is known as the external characteristic. Shown in Figure 24 are the external characteristic curves for generators with various types of excitation. If a generator, which is separately excited, is driven at constant speed and has a fixed field current, the output voltage will decrease with increased load current as shown. This decrease is due to the armature resistance and armature reaction effects. If the field flux remained constant, the generated voltage would tend to remain constant and the output voltage would be equal to the generated voltage minus the IR drop of the armature circuit. However, the demagnetizing component of armature reactions tends to decrease the flux, thus adding an additional factor, which decreases the output voltage.


Figure 24.
DC Generator Curves

In a shunt excited generator, it can be seen that the output voltage decreases faster than with separate excitation. This is due to the fact that, since the output voltage is reduced because of the armature reaction effect and armature IR drop, the field voltage is also reduced which further reduces the flux. It can also be seen that beyond a certain critical value, the shunt generator shows a reversal in trend of current values with decreasing voltages. This point of maximum current output is known as the breakdown point. At the short circuit condition, the only flux available to produce current is the residual magnetism of the armature.
To build up the voltage on a series generator, the external circuit must be connected and its resistance reduced to a comparatively low value. Since the armature is in series with the field, load current must be flowing to obtain flux in the field. As the voltage and current rise the load resistance may be increased to its normal value. As the external characteristic curve shows, the voltage output starts at zero, reaches a peak, and then falls back to zero.
The combination of a shunt field and a series field gives the best external characteristic as illustrated in Figure 24. The voltage drop, which occurs in the shunt machine, is compensated for by the voltage rise, which occurs in the series machine. The addition of a sufficient number of series turns offsets the armature IR drop and armature reaction effect, resulting in a flat-compound generator, which has a nearly constant voltage. If more series turns are added, the voltage may rise with load and the machine is known as an over-compound generator.
Voltage Regulation
Voltage Regulation is the change in terminal voltage with the change in load current at constant speed. A generator has good regulation if the change in voltage between no load and full load is small. If the change is large, the regulation is poor. Expressed in equation form:

Percent Voltage Regulation = (ENL - EFL ) / EFL x 100 or for some compound machines, Percent Voltage Regulation = (EFL - ENL ) / EFL x 100
Figure 24 shows that the regulation of a separately excited machine is better than that of a shunt machine. However, the best regulation is obtained with a compound machine. The series machine has practically no regulation at all and, therefore, has little practical application.

Motor Characteristics

Motor Operation
As previously stated, a conductor moving through a magnetic field due to the motor action also generates a voltage which is in opposition to the applied voltage. This is the back EMF. Then for motor action the voltage equation is:

V = E + IA RA = K1 S + IA RA
where:
V = applied or terminal voltage
E = back EMF
IA = armature current
RA = armature circuit resistance's
K1 = machine constants
= flux per pole
S = speed
When comparing this equation with the voltage equation of a generator, it can be seen that in a generator the generated voltage is higher than the terminal voltage while in a motor the opposite is true. Therefore, as long as the generated voltage is less than the terminal voltage, a machine operates as a motor and takes power from the electrical side, but when the generated voltage becomes greater than the terminal voltage, the machine becomes a generator, supplies electric power, and requires mechanical energy to keep operating.
The back or counter EMF acts as a control for the amount of current needed for each mechanical load. When the mechanical load is increased, the first effect is a reduction in speed. But a reduction in speed also causes a reduction in back EMF, thus making available an increased voltage for current flow in the armature. Therefore, the current increases which in turn increases the torque. Because of this action, a very slight decrease in speed is sufficient to meet the increased torque demand. Also, the input power is regulated to the amount required for supplying the motor losses and output.
Speed Torque Curves
Speed torque curves for the three forms of excitation are shown in Figure 25. In a shunt excited motor, the change in speed is slight and, therefore, it is considered a constant speed motor. Also, the field flux is nearly constant in a shunt motor and the torque varies almost directly with armature current.

In a series motor the drop in speed with increased torque is much greater. This is due to the fact that the field flux increases with increased current, thus tending to prevent the reduction in back EMF that is being caused by the reduction in speed. The field flux varies in a series motor and the torque varies as the square of the armature current until saturation is reached. Upon reaching saturation, the curve tends to approach the straight line trend of the shunt motor. The no load speed of a series motor is usually too high for safety and, therefore, it should never be operated without sufficient load.
A compound motor has a speed torque characteristic which lies between a shunt and series motor.
Speed Regulation
Speed regulation is the change in speed with the change in load torque, other conditions being constant. A motor has good regulation if the change between the no load speed and full load speed is small.

Percent Speed Regulation = (SNL - SFL) / SFL x 100 A shunt motor has good speed regulation while a series motor has poor speed regulation. For some applications such as cranes or hoists, the series motor has an advantage since it results in the more deliberate movement of heavier loads. Also, the slowing down of the series motor is better for heavy starting loads. However, for many applications the shunt motor is preferred.
Motor Starting
When the armature is not rotating, the back EMF is zero and the total applied voltage is available for sending current through the armature. Since the armature resistance is low, an enormous current would flow if voltage were applied under this condition. Therefore, it is necessary to insert an additional resistance in series with the armature until a satisfactory speed is reached where the back EMF will take over to limit the current input.


Losses And Efficiency

Friction and Windage
These losses include bearing friction, brush friction, and windage. They are also known as mechanical losses. They are constant at a given speed but vary with changes in speed. Power losses due to friction increase as the square of the speed and those due to windage increase as the cube of the speed.

Armature Copper Losses
These are the I2 R losses of the armature circuit, which includes the armature winding, commutator, and brushes. They vary directly with the resistance and as the square of the currents.

Field Copper Losses
These are the I2 R losses of the field circuit which can include the shunt field winding, series field winding, interpole windings and any shunts used in connection with these windings. They vary directly with the resistance and as the square of the currents.

Core Losses
These are the hysteresis and eddy current losses in the armature. With the continual change of direction of flux in the armature iron, an expenditure of energy is required to carry the iron through a complete hysteresis loop. This is the hysteresis loss. Also since the iron is a conductor and revolving in a magnetic field, a voltage will be generated. This, in turn, will result in small circulating currents known as eddy currents. If a solid core were used for the armature, the eddy current losses would be high. They are reduced by using thin laminations, which are insulated from each other. Hysteresis and eddy current losses vary with flux density and speed.

Efficiency
For generations or motors, the efficiency is equal to the output divided by the input. However, in a generator, the input is mechanical while the output is electrical. In a motor the opposite is true, therefore:

Motor Efficiency = (Input - Losses) / Input
Generator Efficiency = Output / (Output + Losses)

Section 3: Horsepower Basics

In 18th century England, coal was feeding the industrial revolution and Thomas Newcomen invented a steam driven engine that was used to pump water from coal mines. It was a Scott however, by the name of James Watt, who in 1769 improved the steam engine making it truly workable and practical. In his attempt to sell his new steam engines, the first question coal mine owners asked was "can your engine out work one of my horses?" Watt didn't know since he didn't know how much work a horse could do. To find out, Watt and his partner bought a few average size horses and measured their work. They found that the average horse worked at the rate of 22,000 foot pounds per minute. Watt decided, for some unknown reason, to add 50% to this figure and rate the average horse at 33,000 foot pounds per minute.
What's important is that there is now a system in place for measuring the rate of doing work. And there is a unit of power, horsepower.
If steam engines had been developed some place else in the world, where the horse was not the beast of burden, we might be rating motors in oxen power or camel power. Today, motors are also rated in Watts output.
hp = lb x fpm / 33,000
hp = ft-lb x rpm / 5,252
kW = hp x 0.7457
hpMetric = hp x 1.0138

Horsepower as defined by Watt, is the same for AC and DC motors, gasoline engines, dog sleds, etc.

Horsepower and Electric Motors

Torque = force x radius = lb x ft = T
Speed = rpm = N
Constant = 5252 = C
HP = T x N / C
Torque and DC Motors
T = k Ia
At overload, torque increases at some rate less than the increase in current due to saturation
D2 L and Torque
258AT = 324 D2 L
259AT = 378 D2 L
With the same frame diameter, the 259AT has 17% more D2 L and thus 17% more and 17% more Torque. Motor torque increases with an increase in iron and copper, combined with current. It can then be said that it takes iron and copper to produce torque and torque makes products. Or to put it another way, what you purchase to make product is TORQUE and that is IRON and COPPER. The rate of doing work is power and HORSEPOWER is a unit of power.
Speed and DC Motors
Shunt wound DC motors
With motor load, temperature and field current held constant, speed is controlled by armature voltage.

E = ((Z / a) x x P x (N / 60) x 10-8 ) + (I Ra + I Rip + I Rb )
The sum of the voltage drop in the armature circuit can be represented as IR
N = (E - IR) / K
Speed example: given motor is design G6219, frame MC3212, 50 hp, 1150 rpm, 500 volt armature, 85 amps full load, 0.432 armature circuit resistance hot, 0.206 armature circuit resistance cold
Edrop = IR = 85 amp x 0.432 = 36.72 volts
500 v arm - 36.72 v drop = 463.28 working volts
Volts per rpm = 463.28 / 1150 rpm = 0.40285
Nbase speed = 1150 rpm = (500 v - 36.72 v) / 0.40285
With 250 v on the armature, there is 213.28 working volts (250 - 36.72)
213.28 / 0.40285 = 529 rpm (not 1/2 speed, 575 rpm)
N = 529 rpm = (250 v - 36.72 v) / 0.40285
N = (E - IR) / K = (E - IR) / 0.40285
K changes with changes in load and temperature
HPMetric = HP x 1.0138
kW = HP x 0.7457
Last Updated September 1, 1998


Copyright ©2007, Baldor Electric Company.
All Rights Reserved.

Friday, February 27, 2009

The Refrigeration Cycle 1


The refrigerator in your kitchen uses a cycle that is similar to the one described in the previous section. But in your refrigerator, the cycle is continuous. In the following example, we will assume that the refrigerant being used is pure ammonia, which boils at -27 degrees F. This is what happens to keep the refrigerator cool:
  1. The compressor compresses the ammonia gas. The compressed gas heats up as it is pressurized (orange).
  2. The coils on the back of the refrigerator let the hot ammonia gas dissipate its heat. The ammonia gas condenses into ammonia liquid (dark blue) at high pressure.
  3. The high-pressure ammonia liquid flows through the expansion valve. You can think of the expansion valve as a small hole. On one side of the hole is high-pressure ammonia liquid. On the other side of the hole is a low-pressure area (because the compressor is sucking gas out of that side).
  4. The liquid ammonia immediately boils and vaporizes (light blue), its temperature dropping to -27 F. This makes the inside of the refrigerator cold.
  5. The cold ammonia gas is sucked up by the compressor, and the cycle repeats.

By the way, if you have ever turned your car off on a hot summer day when you have had the air conditioner running, you may have heard a hissing noise under the hood. That noise is the sound of high-pressure liquid refrigerant flowing through the expansion valve.
Pure ammonia gas is highly toxic to people and would pose a threat if the refrigerator were to leak, so all home refrigerators don't use pure ammonia. You may have heard of refrigerants know as CFCs (chlorofluorocarbons), originally developed by Du Pont in the 1930s as a non-toxic replacement for ammonia. CFC-12 (dichlorodifluoromethane) has about the same boiling point as ammonia. However, CFC-12 is not toxic to humans, so it is safe to use in your kitchen. Many large industrial refrigerators still use ammonia.
In the 1970s, it was discovered that the CFCs then in use are harmful to the ozone layer, so as of the 1990s, all new refrigerators and air conditioners use refrigerants that are less harmful to the ozone layer.

Tuesday, February 24, 2009

Container-Shipping-Logistics Operation Code


Depot Operation Code

actual gross weight
The sum of the container weight plus the payload contained in it.
actual payload
Maximum allowable weight of payload (actual weight minus tare weight).
actual weight
Gross shipping weight.
box pallet
A pallet with at least three fixed, removable, or collapsible vertical sides.
break bulk
Cargo transported not in a container. It may be in loose packages or in loose form, such as machinery.
break bulk cargo
See break bulk.
cargo seal
The metal device inserted into the handle assembly on the door of the container to prevent or to detect entry. The seal has a number that is recorded. In addition, this number is often noted on the bill of lading. The sophistication of seals can range from a simple, numbered plastic tag - called an entry seal and used on an empty container - to an electronic seal that immediately indicates through global electronic positioning technology when and where it has been broken.
cargo tonnage
The weight ton in the United States is the short ton, 2,000 pounds, or the long ton, 2,240 pounds. In British countries it is the English long ton, or gross ton, of 2,240 pounds. In France and other countries having the metric system, the weight ton is 2,204.62 pounds. The measurement ton is usually 40 cubic feet, but in some instances a larger number of cubic feet is taken as a weight ton. Most ocean freight is taken at weight or measurement (W/M), ship's option.
cargo weight
The weight of the cargo. Cargo weight plus tare weight equals gross weight.
carrying temperature
A narrow, prescribed range of temperatures in a container during transit that maintains the ideal temperature in the product and protects the product from harm. This information is displayed on a label attached to the container.
chassis
A wheeled carriage onto which a container is mounted for over-the-road conveyance. More specifically, it is a skeletal frame, semi-trailer which is equipped with license, lights, reflectors, brakes, etc., to meet the legal operating codes and requirements of the jurisdictions within which it operates. This unit has locking devices that secure the container to the frame. In the case of container yard operations, it is a skeletal trailer, generally without a license for use on the public roads, for moving containers within a yard. Also, the part of a motor vehicle that includes, the frame, suspension system, wheels, steering mechanism etc., but not the engine or the body.
container
When used in an intermodal industry context, this refers to a steel or aluminum box into which goods or a commodity are packed for shipment.
container contamination
A container is considered contaminated when residue of previous cargo cannot be cleaned by normal sweeping or by normal steam cleaning. The remedy may then be:
· structural repair,
· removal of contaminated floor boards,
· partial or full refurbishment,
· chemical cleaning,
· fumigating,
· decontamination, or
· deodorizing.
container damage
Defined by one or more physical defects on a container that affects the cargo carrying capabilities of the unit. This could have been caused by a single or a series of events, such as impact, abrasion, or contamination. Damaged containers are inspected and repaired to the ICII standards.
container load
A load sufficient in size to fill a container either by cubic measurement or by weight.
container load plan
A list and a graphic picture of the inside of a container showing where and how the cargo is stowed and the loading sequence.
containerizable cargo
Cargo that will fit into a container and result in an economical shipment consistent with delivery requirements.
controlled atmosphere
A term used in reference to a refrigerated container to indicate it is a type that permits the temperature within the container to be controlled. The reason that this is important is so a gas such as nitrogen can be maintained in a stable condition within the container. Nitrogen reduces the spoilage rate of fruits and vegetables.
corner post
A vertical structural member at each of the four corners of a container. These are made onto a square unit by top and bottom horizontal posts. The vertical and horizontal members are connected at the corner castings, thereby forming an end frame or corner structure.
cubic capacity
Has two meanings: (1) the carrying capacity of a container in terms of cubic measurement; and (2) the cubic space available for the stowage of cargo.
cubic feet per minute
Unit of measurement for the movement of a volume of gas or liquid per unit of time.
cubic foot
A measurement of 12 inches by 12 inches by 12 inches or 1,728 cubic inches.
cubic meter
A measurement of 1 meter by 1 meter by 1 meter. Abbreviated: CBMCM
D20
Dry 20-foot container.
D40
Dry 40-foot container.
deadweight tonnage
The number of long tons (see ton) of cargo, stores, water, and fuel a vessel can transport. Relative to cargo, the weights for stores, water, and fuel are not significant. You can use DWT as a quick reference for the cargo carrying capacity of a ship.
deadweight cargo
Cargo of such a nature that one long ton is stowed in less than 70 cubic feet.
dry cargo When used in a tariff, this means cargo other than liquid cargo or cargo requiring temperature control.
dry cargo
When used in a tariff, this means cargo other than liquid cargo or cargo requiring temperature control.
dunnage
Material used in stowing or bracing cargo to prevent movement.
FEU
Abbreviation for the International Standards Organization designated "Forty-Foot Equivalent Unit."
flat rack
See flat rack container.
flat rack container
A special container for cargo too long or wide for standard containers.
floor loading
Static weight of cargo and the dynamic force of handling equipment, such as a forklift, for a particular container.
forklift pockets
Openings in the sides of containers for the insertion of forks by a forklift.
forklift truck
A three or four wheeled mechanical unit with forks at the front designed for lifting, carrying, and stowing cargo, pallets, or containers.
forty-foot equivalent unit
Abbreviated FEU. Refers to container size standard of 40 feet. 1 40-foot container equals 2 TEU. This equivalency standard was set by the ISO.
full container load
A container loaded, completely or almost, to its maximum weight limit or cubic content.
gallon
One U.S. gallon equals 231 cubic inches or 0.1337 cubic feet.
genset
Generator used to supply power to a refrigerated container.
GOH
Garment on hangar. Indicates a container that has been converted from a dry box to a garment container.
gooseneck
On a drop-frame chassis, the gooseneck is the upper level at the front of the chassis together with the structure connecting it to the lower level behind it. The gooseneck on the chassis structure fits into the gooseneck tunnel recess of containers built with this feature. This provides the securing and stability for the container at the front. The rear of the container is secured with the normal twistlock assembly.
gooseneck tunnel
The recess in the front portion of a container understructure into which the gooseneck structure of a chassis fits.
gross ton
2,240 pounds. See short ton.
gross tonnage
This is not a measurement of weight as we traditionally think of it. It is a measurement of the amount of vessel space: a ton is 100 cubic feet. A ship's gross tonnage is all the cubic feet in its enclosed spaces: cargo holds, engine room, and deck house divided by 100. See net tonnage.
gross weight
As a measurement, gross means the item you are evaluating consists of the overall total exclusive of deductions. When, for example, referring to an in-gate operation this is the total weight of the equipment - such as tractor, including fuel and driver - and chassis and cargo. But, if you were referring to the gross weight of the container only, this would be a combination of the container tare weight plus the cargo weight.
grounding
Removing the container from the stack train and putting it on a chassis.
half height container
An open top container, sometimes fitted with removable covers, that is 4'3''/1.30m high.
high cube
A container that exceeds 8 feet 6 inches in height.
in transit
In passage.
inflatable dunnage
Flexible bags usually made from vinyl material; can be inflated within the void spaces of a stow to prevent movement of the cargo.
insulated container
A container insulated on the walls, roof, floor and doors, to reduce the effect of external temperatures on the cargo.
International Standards Organization
An organization founded in the late 1940's and headquartered in Geneva, Switzerland. Through the participation of its members, it establishes many world standards; for example, ISO 9002 as a business practice. In the intermodal area, the ISO is best known for establishing in the mid 1960's the standard for the size of a container, including all its components, such as the specifications for the corner casting. This reversed the situation where, by the time there were 20,000 containers worldwide in 1965, there were 11 different sizes. The resulting uniformity coordinated and established by the ISO permitted the evolution from containerization to intermodalism.
ISO
See International Standards Organization.
known damage
Damage discovered before or at the time of delivery of a shipment.
known loss
A loss discovered before or at the time of delivery of a shipment.
KT
Kilo or metric ton. Equals 2,204.6 pounds.
laden
Means the same as "loaded (aboard a vessel)."
lash
To hold goods in position by the use of securing devices such as wire rope, lines, chains and straps.
lashing fitting
A cargo securing device in the floor fixed to the interior side panels of a container that provide for the lashing or securing of cargo.
lashing point
See lashing fitting.
lashing rod
A stout metal rod used in on-deck container stowage that secures containers to the deck. It ties a container corner casting to a fitting on the deck or on the lashing bridge. Used in conjunction with the interbox connector, this stabilizes the stacks on deck. This is necessary to compensate for the effects of ship movement in the open sea.
load
To load a vehicle or container. The freight in a vehicle or container. A container filled with freight that is moved from the customer-designated origin to the customer-designated destination. To load a program into a computer after the program has been translated into machine code. Any procedure for getting a computer or other device ready to operate by providing that device with the magnetic tape or disks that it needs to function.
long ton
2,240 pounds. See also ton.
m
Abbreviations for: A meter, or 39.37 inches.
max.
Maximum.
maximum cube
A level of cube utilization that closely approximates the stated cubic capacity of a container.
maximum gross weight
Weight of a container and its payload.
maximum payload
Maximum cargo that can be loaded into a container either by weight or volume.
MBM
1,000 board feet. 1 MBM equals 2,265 C.M.
meter
1 meter equals 39.37 inches. Also spelled metre.
metre
An alternative spelling of meter.
metric ton
2,204.6 pounds; or 40 cubic feet - used in water transportation rate-making. The same as a measurement ton. Also see ton.
min.
Minimum.
min. wt.
Minimum Weight.
modified atmosphere
Abbreviated MAMOS. A blend of gases tailored to a specific load of cargo that replaces the normal atmosphere within a container.
MT
Measurement ton. See metric ton.
net short ton
2,000 pounds.
net tare weight
The weight of an empty cargo-carrying piece of equipment plus any fixtures permanently attached.
net ton
Metric ton.
net tonnage
Net tonnage measures volume of airspace. Like deadweight tonnage, it is used to rate a ship's cargo carrying capacity.
To determine NT, the cubic footage of all non-cargo spaces - crew accommodations, machinery and navigation areas, the engine room, and the fuel and water tanks - are measured. This measurement is divided by 100 to convert it to net tons. This figure is then subtracted from the gross tonnage figure. The result is net tons of cargo carrying capacity in cubic measure. See also gross tonnage.
net weight
When referring to goods, this is the weight of the product exclusive of all packaging.
nose
Front of the container.
NT
Net ton.
obnoxious cargo
Cargo that can by its nature contaminate its container, the vessel, or other cargo, for example: hides or fish meal.
open top
See open top container.
open top container
container fitted with a solid removable roof, or with a tarpaulin roof that can be loaded or unloaded from the top.
optimum cube
The highest level of cube utilization that can be achieved when loading cargo into an ocean-freight container.
overheight cargo
Cargo extending above the height of an open top container.
pallet
Standard size platform on which packages can be stacked and then unitized - for example, with bands or plastic wrap for easy movement by a forklift truck. See pallet wrapping machine. Europe, the 1,200mm by 1,000mm pallet is in general use. The U.K. equivalent is 48 inches by 40 inches. Growing in popularity is the 48 inch by 48 inch pallet.
palletized cargo
Individual items of cargo loaded on a pallet.
payload
General, this is the revenue-producing or useful load a means of transportation can carry. Translated to intermodal language, it is a container's maximum permitted cargo weight, not including cargo securing devices and dunnage.
Pti
Pre trip inspections
reefer
Refrigerated container, equipment or cargo.
reefer cargo
Industry language for the term "refrigerated cargo," which cargo requiring temperature control. See refrigeration.
reefer container
Industry language for the term "refrigerated container."
refrigerated container
See refrigeration.
refrigeration
In its simplest terms, refrigeration is simply the removal of heat from one medium to another by use of inert gas. In the case of refrigerated containers, it is removal of heat from inside the box - the cargo and surrounding air - to outside the box. The inert gas most commonly used is named R-12.
relative humidity
A percentage of the amount of moisture in air relative to saturated air at the same temperature.
RFR
Reefer.
seal
Metal strip and lead fastener used for locking freight car or container doors. Seals are numbered for recording purposes. A seal is generally affixed after Customs exams have been completed, and prior to the container being loaded on the first conveyance. See cargo seal.
set point temperature
The point, or points, at which the thermostat in a refrigerated container is set, that will maintain the ideal pulp temperature in the product.
setting
A notation on the transport document, known as a bill of lading in the case of ocean carriage, stating the temperature at which the cargo must be maintained. This term is most commonly used in relation to a refrigerated container. Also known as air delivery temperature.
setting/air delivery temperature
See setting.
short ton
Abbreviated ST. 2,000 pounds. See also ton.
skid
Refers to planks placed under a box, crate or piece of machinery to enable the piece to be easily handled by a mechanical lifting device. Battens, or a series of parallel runners, fitted beneath boxes or packages to raise them clear of the floor to permit easy access of forklift blades or other handling equipment.
skip sheet
A flat piece of cardboard that replaces a pallet.
special commodities
Highly perishable commodities that require special handling to arrive at their destination in optimum condition. Some examples are fish, meat, photographic film, fruit, and some candies.
special container
A container designed to carry overheight (open-top container), overwidth (flat rack container) or liquid (tank container) cargo.
stack
Containers stowed more than one high and in a orderly way in one place in a Container Yard, CFS, depot, or on a vessel.
standard ton
Same as short ton. See also ton.
stow
The placing and securing of cargo or containers on a vessel or on an aircraft. This also includes placing and securing cargo in a container.
stow plan
A diagrammatic picture of the vessel's cargo hatches showing the location of cargo or containers.
stowage
A marine term referring to loading freight into ships' holds.
stowage factor
The ratio of a cargo's cubic measurement to its weight, expressed in cubic feet to the ton or in cubic metres to the tonne. It is an expression of the total quantity of cargo which can be loaded in a space.
stowage instructions
Details given by the shipper or his agent about the way cargo is to be stowed.
stowage plan
See stow plan.
stuff
To load a container.
stuffing
Loading cargo into a container. Also known as vanning.
superimposed load
The static and dynamic load forces imposed downward externally and vertically on the structure of a container.
tank container
A specially constructed container for transporting liquids and gases in bulk.
tare weight
The weight of equipment that is empty, that is, not carrying cargo. For example, an empty FEU of steel construction weighs between 6,000 to 8,380 pounds/2,860 to 3,800 kilograms. See also cargo weight and gross weight.
tarpaulin
Waterproof fabric used for covering the top of an open top container.
temperature recorder
A waterproof device to permanently record the inside temperature of operating refrigerated containers. The device may be computerized, mechanical, or both. The chart onto which the information is inscribed mechanically is called the Partlow chart. Mr. Partlow was the inventor.
TEU
Abbreviation for the International Standards Organization designated "Twenty Foot Equivalent Unit".
tolerance
A weight allowance made to reconcile weight variations of certain commodities.
ton
A measurement of weight:
. A short ton, used for rough calculations, is 2,000 pounds. This "abbreviated" ton is used in cargo operations, particularly when working with break bulk cargo. It useful for doing mental quick calculations.
. A long ton, also known as gross ton, used for more precise calculations, is 2,240 pounds. The genesis of the long ton goes back to the 13th century, when merchant ships carried large cargoes of wine in giant casks, which were called "tuns." The number of tuns a ship could carry was a rough gauge of her capacity. By the 15th century, England had established a standard for the wine-filled tun: a capacity of 250 gallons, which converted to 2,240 pounds. In the 17th century, long after wine ceased to be a major cargo, usage brought about the modern spelling of ton.
A measurement of cubic volume
. Measurement ton is 40 cubic feet. Cargo can be taken at either weight or cubic volume.
tonnage
This term is used in various contexts in the maritime industry to describe:
· the cubic capacity of a vessel,
· the displacement of a vessel in tons of water,
· the total weight of the cargo, or
· a fee charged per ton of cargo at a port, pier, dock or canal.
tonne
Another way to spell the word ton.
twenty-foot equivalent unit
Abbreviated TEU. Refers to container size standard of 20 feet. 2 20-foot containers equal 1 FEU. This equivalency standard was set by the ISO.
two-way pallet
A pallet so designed that the forks of a fork lift truck can be inserted from 2 sides only.
unit load
Packages loaded on a pallet in a crate or any other way that enables them to be handled at one time as a unit.
unitization
Loading 1 or more large items of cargo onto a single piece of equipment, such as a pallet. The consolidation of a quantity of individual items into 1 large shipping unit for easier handling.
unitize
To consolidate several packages into 1 unit; to strap, band, or otherwise attach the several packages together.
unitized cargo
See unitize.
unitized load
A number of cartons or other pieces of cargo that are loaded onto a container as a single unit, typically either on a platform called a pallet, or a slipsheet. This type of handling fa ciliates handling by a load truck.
unstuff
Unloading a container.
vanning
See stuffing.
W
A tonne of one thousand kilogrammes. See also ton.
weight cargo
A cargo on which the transportation charge is assessed on the basis of weight.
weight limits
Once a container loaded with cargo has been put on a chassis and this unit has been attached to a tractor, there is another consideration: the limitations of the weight-bearing capacity of the road system between the beginning and end of the over-the-road segment. In the U.S., these limitations are called "bridge laws," as they are usually based on the weight that can be supported by a bridge.
weights and measures
Measurement ton = 40 cubic ft. Net ton, or short ton = 2,000 lbs. Gross ton/long ton = 2,240 lbs. Metric ton/kilo ton = 2,204.6 lbs. Cubic meter = 35.314 cubic ft.

Monday, February 9, 2009

Container ISO Codes

Sometimes we need to identify containers by looking at the ISO codes. I have listed mainly use ISO codes for Depot users/surveyors.
Container ISO-Codes

ISO        LxWxH                Description of the container
20G0    20 x 8 x 8 20´      general container
20G1    20 x 8 x 8 20´      general container with ventilation holes
20H1    20 x 8 x 8 20´      port hole reefer container
20T0    20 x 8 x 8 20´      tank container
22G0    20 x 8 x 8,5 20´   general container
22G1    20 x 8 x 8,5 20´   general container with ventilation holes
22V0    20 x 8 x 8,5 20´   highly ventilated container
22R0    20 x 8 x 8,5 20´   integral reefer container

22R1    20 x 8 x 8,5 20´    integral reefer/heated container
22H2    20 x 8 x 8,5 20´    thermal insulated external container
22U0    20 x 8 x 8,5 20´    open top container
22U1    20 x 8 x 8,5 20´    open top container removable top
22P1    20 x 8 x 8,5 20´    flat rack with fixed ends
22P2    20 x 8 x 8,5 20´    flat with fixed corner posts only
22P3    20 x 8 x 8,5 20´    flat with collapsible ends
22P5    20 x 8 x 8,5 20´    open sided container
22T0    20 x 8 x 8,5 20´    tank container - non dangerous liquid
22T5    20 x 8 x 8,5 20´    tank container
22B0    20 x 8 x 8,5 20´    dry bulk container
25G0    20 x 8 x 9,5 20´    genaral high cube container (9,6)
25R1    20 x 8 x 9,5 20´   integral high cube reefer container (9,6)
28U1    20 x 8 x 4 20´      half height open top container
26T0    20 x 8 x 4 20´       half height tank container
28P0    20 x 8 x 4 20´      platform flat
 
42G0    40 x 8 x 8,5 40´    genral container
42G1    40 x 8 x 8,5 40´    genral container with ventilation holes
42V0    40 x 8 x 8,5 40´    highly ventilated container
42R0    40 x 8 x 8,5 40´    integral reefer container
42U1    40 x 8 x 8,5 40´    open top container
42U1    40 x 8 x 8,5 40´    open top container with removable top parts
42P1    40 x 8 x 8,5 40´    flat rack with fixed ends
42P2    40 x 8 x 8,5 40´    flat with corners posts only
42P3    40 x 8 x 8,5 40´    flat with collapsible ends
42P5    40 x 8 x 8,5 40´    open sided container
42B0    40 x 8 x 8,5 40´    dry bulk container
45G0    40 x 8 x 9,5 40´    general container high cube (9,6)
45R1    40 x 8 x 9,5 40´    integral reefer container high cube (9,6)
48U1    40 x 8 x 4 40´       half height open top container
48P0    40 x 8 x 2 40´        platform flat

Tuesday, February 3, 2009

Fresh Air Exchange Flow Rate Conversion. (Update)























































I'm guessing;
Cmh = cubic meters per hour
cfm = cubic feet per minute
m3/hr * 35.3ft3/m3 * hr/60minutes = ft3/minute
1 cmh = 0.5883 cfm
sample

19 cmh x 0.5883 = 11.1777 cfm
answer = 11 cfm
formula to convert cmh to cfm

1 cbm = 1.6990108
sample
30 cfm x 1.6990108 = 50.070324 cbm/cmh
answer = 50 cbm or cmh
formula to convert cfm to cbm/cmh